Resources for the Glass Block Industry can be found here. If you don’t find what you are looking for, please contact us today. Our sales representatives are ready to help.
Color Glass Block - Exterior Applications (Basic Line - Soft Shades, Design Line - Colored Glass)
GBW-Color-Glass-Block-Exterior-Applications.pdfColor Glass Block - Interior Applications (New Color Collection, Mendini Collection, Basic Line - Brilly)
GBW-Color-Glass-Block-Interior-Applications.pdf8x8x4 Thickset 90 - Structural N.A.M.I. Certification (NI013848.03-R5) - 09.29
NI013848.03-R5.pdf8x8x4 Thickset 90 - Structural N.A.M.I. Certification (NI013848.05-R5) - 09.29
NI013848.04-R5.pdf12x12x4 Premiere - Structural N.A.M.I. Certification (NI013848-R5) - 09.29
NI013848-R5.pdf12x12x4 Premiere - Structural N.A.M.I Certification (NI013848.01-R5) - 09.29
NI013848.01-R5.pdf8x8x3 Vistabrik - Structural N.A.M.I. Certification (NI013848.02-R5) - 09.29
NI013848.02-R5.pdfASTM E-119 HEAD Detail - 120 min. Wall Rated FIRE GLASS BLOCK at CMU-Bond Beam
FR-113-ASTM-E-119-HEAD-120-MIN-WALL-RATED-FIRE-GLASS-BLOCK-AT-CMU-BOND-BEAM.pdfASTM E-119 HEAD Detail - 120 min Wall Rated FIRE GLASS BLOCK at Metal Stud Wall
FR-114-ASTM-E-119-HEAD-120-MIN-WALL-RATED-FIRE-GLASS-BLOCK-AT-METAL-STUD-WALL.pdfASTM E-119 JAMB Detail- 120 min Wall Rated FIRE GLASS BLOCK at CMU
FR-124-ASTM-E-119-JAMB-120-MIN-WALL-RATED-FIRE-GLASS-BLOCK-AT-CMU.pdfASTM E-119 JAMB Detail - 120 min Wall Rated FIRE GLASS BLOCK at Metal Stud Wall
FR-125-ASTM-E-119-JAMB-120-MIN-WALL-RATED-FIRE-GLASS-BLOCK-AT-METAL-STUD-WALL.pdfASTM E-119 SILL Detail - 120 min Wall Rated FIRE GLASS BLOCK at CMU Wall
FR-133-ASTM-E-119-SILL-120-MIN-WALL-RATED-FIRE-GLASS-BLOCK-AT-CMU-WALL.pdfASTM E-119 SILL Detail - 120 MIN WALL RATED FIRE GLASS BLOCK AT Metal Stud WALL.pdf
FR-134-ASTM-E-119-SILL-120-MIN-WALL-RATED-FIRE-GLASS-BLOCK-AT-Metal-Stud-WALL.pdfData - Characteristics for up to 2-hour Fire Rated Wall Block 1919/13 F-120
SGB-046-1919_13-F-120-Data-Characteristics-Sheet-US-EU_12-23.pdfASTM E119-20, Standard Test Methods for Fire Tests of Building Construction and Materials UL 263-19, UL Standard for Safety, Fire Tests of Building Construction and Materials CAN/ULC-S101-14, Standard Methods of Fire Endurance Tests of Building Construction and Materials
ASTM-E119-Summary-SGBI042921-110S.pdfSeries “1919/13 F120" Fire Rated Wall Block Unit. ASTM E119-20, UL 263-19, CAN/ULC-S101-14
NI015719.pdfFEMA P-361 Safe Rooms Tornadoes Hurricanes
FEMA-P-361-Safe-Rooms-Tornadoes-Hurricanes_low.pdfFEMA P-320 Building Safe Room Home Small Business
FEMA-P-320-Building-Safe-Room-Home-Small-Business_low.pdfFEMA - Rebuild With Flood-Resistant Materials
Rebuild-With-Flood-Resistant-Materials-_-FEMA.gov_.pdfFEMA - Build with Flood Damage Resistant Materials
Glass-Block-FEMA-Flood-Resistant.pdfFEMA Flood Damage Resistant Materials
FEMA-Flood-Damage-Resistant-Materials.pdfFEMA P-499 Technical Fact Sheet-1.7 Coastal Building Materials
FEMA-P-499-Technical-Fact-Sheet-1.7-Coastal-Building-Materials.pdfSGBI080120-22 Final Testing Results
SGBI080120-22-Final-Testing-Results-1.pdfFusion Technology Custom Colored Glass Blocks
Fusion-Technology-Installation-Guide_V2.1.15.2021-2.pdfNorth American Design Guide
SGB-041-North-American-Design-Guide-2021_0.pdfTexas Department of Insurance - Residential Hurricane Resistant Window with Thickset 90 (Provantage® Silicone) for Glass Block
TDI-WIN62-Provantage-Product-Evaluation.pdfTexas Department of Insurance - Non-Impact Resistant (Mortar) Specifications for Glass Block Installation
TDI-WIN63-Mortar-Product-Evaluation.pdfMiami/Dade NOA Residential Hurricane Resistant Windows w THICKSET® 90 and ProVantage® System.pdf - Small & Large Missile Impact (Lightwise® / Residential)
Miami-Dade-NOA-20111008-Residential-Hurricane-Resistant-Windows-w-THICKSET®-90-and-ProVantage®-System.pdfSGB-014 Residential Hurricane Resistant GB Windows
SGB-014-Residential-Hurricane-Resistant-GB-Window.pdfFL25880_R0_II_RHRW-001 SS 2018-03-29
FL25880_R0_II_RHRW-001-SS-2018-03-29-1.pdfFL25880_RO_AL_PER4813 SS 2018-04-13
FL25880_R0_AE_PER4813-SS-2018-04-13-1.pdfKWIK'N-EZ Silicone Installation System - English
SGB-032-ProVantage-Silicone-Installation-System-05_28_21-EN_ES_0-1.pdfMyMiniGlass Silicone Installation System - English
SGB-032-ProVantage-Silicone-Installation-System-05_28_21-EN_ES.pdfHorizontal Stiffener - Intermediate Horizontal Shelf Angle Support in Vertical Panels
VP-361-HORIZONTAL-STIFFENER-INTERMEDIATE-HORIZONTAL-SHELF-ANGLE-SUPPORT-IN-VERTICAL-PANELS-DETAIL-1-1.pdfHORIZONTAL STIFFENER - VetropienoTM Intermediate Horizontal Support in Multiple Vertical Panels - Shelf Angle-Detail
VP-360-HORIZONTAL-STIFFENER-VETROPIENO-INTERMEDIATE-HORIZONTAL-SUPPORT-IN-MULTIPLE-VERTICAL-PANELS-SHELF-ANGLE-DETAIL-1.pdfHORIZONTAL STIFFENER - VetropienoTM Structural Horizontal Support in Multiple Panels-Detail
VP-352-HORIZONTAL-STIFFENER-VETROPIENO-STRUCTURAL-HORIZONTAL-SUPPORT-IN-MULTIPLE-PANELS-DETAIL-1.pdfVERTICAL STIFFENER - VetropienoTM Intermediate Vertical Support in Multiple Horizontal Panels-Detail
VP-351-VERTICAL-STIFFENER-VETROPIENO-INTERMEDIATE-VERTICAL-SUPPORT-IN-MULTIPLE-HORIZONTAL-PANELS-DETAIL-1.pdfVERTICAL STIFFENER - VetropienoTM Triangular Anchoring Support at Corner-Detail
VP-350-VERTICAL-STIFFENER-VETROPIENO-TRIANGULAR-ANCHORING-SUPPORT-AT-CORNER-DETAIL-1.pdfSILL - VetropienoTM in Concrete Floor Slab-Detail
VP-332-SILL-VETROPIENO-IN-CONCRETE-FLOOR-SLAB-DETAIL-1.pdfSILL - VetropienoTM in Metal Stud Wall w Brick Veneer-Detail
VP-331-SILL-VETROPIENO-IN-METAL-STUD-WALL-BRICK-VENEER-DETAIL-1.pdfSILL - VetropienoTM in Metal Stud Wall with Synthetic Plaster-Detail
VP-330-SILL-VETROPIENO-IN-METAL-STUD-WALL-WITH-SYNTHETIC-PLASTER-FINISH-DETAIL-1.pdfJAMB - VetropienoTM in Metal Stud Wall with Brick Veneer-Detail
VP-321-JAMB-VETROPIENO-IN-METAL-STUD-WALL-WITH-BRICK-VENEER-FINISH-DETAIL-1.pdfJAMB - VetropienoTM in Metal Stud Wall w Synthetic Plaster-Detail
VP-320-JAMB-VETROPIENO-IN-METAL-STUD-WALL-SYNTHETIC-PLASTER-DETAIL-1.pdfHEAD - VetropienoTM in Metal Stud Wall with Brick Veneer-Detail
VP-311-HEAD-VETROPIENO-IN-METAL-STUD-WALL-WITH-BRICK-VENEER-DETAIL-1.pdfHEAD - VetropienoTM in Metal Stud Wall-Detail
VP-310-HEAD-VETROPIENO-IN-METAL-STUD-WALL-DETAIL-1.pdfVistabrik® - Horizontal Shelf Intermediate Horizontal Support in Multiple Vertical Panels-Detail
VB-260-VISTABRIK-HORZ.-SHELF-INTERMEDIATE-HORIZONTAL-SUPPORT-IN-MULTIPLE-VERTICAL-PANELS-DETAIL-1.pdfVERTICAL STIFFENER - Vistabrik® Triangle Anchor Intermediate Support in Multiple Horizontal Panels-Detail
VB-250-VISTABRIK-TRIANGLE-ANCHOR-INTERMEDIATE-SUPPORT-IN-MULTIPLE-HORIZONTAL-PANELS-DETAIL-1.pdfSILL - Vistabrik® in CMU Wall-Detail
VB-233-SILL-VISTABRIK-IN-CMU-BRICK-WALL-DETAIL-1.pdfSILL - Vistabrik® in CMU Wall-Detail
VB-232-SILL-VISTABRIK-IN-CMU-WALL-DETAIL-1.pdfSILL - Vistabrik® in Metal Stud Wall-Detail
VB-231-SILL-VISTABRIK-IN-METAL-STUD-WALL-DETAIL-1.pdfSILL - Vistabrik® in Metal Stud Wall with EIFS-Detail
VB-230-SILL-VISTABRIK-IN-METAL-STUD-WALL-WITH-SYNTHETIC-PLASTER-FINISH-DETAIL-1.pdfJAMB - Vistabrik® in CMU or Other Masonry with Brick Veneer-detail
VB-223-JAMB-VISTABRIK-IN-C.M.U.-OR-OTHER-MASONRY-WITH-BRICK-VENEER-DETAIL-1.pdfJAMB - Vistabrik® in CMU or Other Masonry-Detail
VB-222-JAMB-VISTABRIK-IN-C.M.U.-OR-OTHER-MASONRY-DETAIL-1.pdfJAMB - Vistabrik® in Metal Stud Wall w EIFS-Detail.pdf
VB-220-JAMB-VISTABRIK-IN-METAL-STUD-WALL_EIFS-DETAIL-1.pdfHEAD - Vistabrik® in CMU or Masonry Wall with Brick Veneer-Detail
VB-213-HEAD-VISTABRIK-IN-CMU-OR-MASONRY-WALL-WITH-BRICK-VENEER-DETAIL-1.pdfHEAD - Vistabrik® in CMU Wall-Detail
VB-212-HEAD-VISTABRIK-IN-CMU-WALL-DETAIL-1.pdfHEAD - Vistabrik® in Metal Stud Wall w Brick Veneer-Detail.pdf
VB-211-HEAD-VISTABRIK-IN-METAL-STUD-WALL_BRICK-DETAIL-1.pdfHEAD - Vistabrik® in Metal Stud Wall with EIFS-Detail
VB-210-HEAD-VISTABRIK-IN-METAL-STUD-WALL_EIFS-DETAIL-1.pdfTypical Detail Information and Code Limitations
TYPICAL-DETAIL-INFORMATION-AND-CODE-LIMITATIONS.pdfTypical Detail Information and Code Limitations - Pegasus Q19
Pegasus-Q19-TYPICAL-DETAIL-INFORMATION-AND-CODE-LIMITATIONS_0.pdfTexas Department of Insurance - Non-Impact Resistant (Mortar)
TDI-WIN63-Mortar-Product-Evaluation.pdfTexas Department of Insurance - Residential Hurricane Resistant Window with Thickset 90 (Provantage® Silicone)
TDI-WIN62-Provantage-Product-Evaluation.pdfTAS 201, 202, 203 Certification NI013704.05 - Residential Hurricane 80 psf
NI013704.05_High-Performance-Hurricane-Res-80mph.pdfTAS 201, 202, 203 Certification NI013704.04 - Residential Hurricane 68 psf
NI013704.04_High-Performance-Hurricane-Res-68mph.pdfTAS 201, 202, 203 Certification NI013704.03 - Residential Hurricane 80 psf
NI013704.03_Residential-Hurricane-100-psf.pdfTAS TAS 201, 202, 203 Certification- Lightwise® /Commercial 2-pc Alum 80 psf NI013687.01-R1
NI013687.01-R1_TS90-High-Performance-Hurricane-2-pc-Alum-80mph.pdfTAS 201, 202, 203 Certification NI013687.02-R1 - Lightwise® / Commercial 2-pc Alum TS90 68 psf
NI013687.02-R1__TS90-High-Performance-68psf-Hurricane.pdfTAS 201, 202, 203 LWA Hurricane Certification- Lightwise® / Commercial 2-pc Alum 100 psf NI013687-R1
NI013687-R1_TS90-High-Performance-Hurricane-2-pc-Alum-100mph.pdfState of Florida - Small & Large Missile Impact - Thickset®90 ProVantage® Silicone System (Residential)
FL5357_R7_C_CAC_NOA-20-1110.08-Residential-Hurricane-Resistant-Windows-w-THICKSET®-90-and-ProVantage®-System.pdfState of Florida - Small & Large Missile Impact Thickset®90 Provantage® Silicone System (Commercial)
FL17313_R3_C_CAC_NOA-20-1110.06-High-Performance-Hurricane-Resistant-Window.pdfState of Florida - Small Missile Impact, 4" Thickset90®, 3" Solid Glass Block (Mortar)
FL1363_R8_C_CAC_NOA-20-1110.07-4-Hollow-and-3-Solid-Glass-Block-Systems-with-Mortar.pdfSmart Home ESSENTIAL GUIDE Smart Solutions for Interior Design Multi-lingual
SmartHome_low.pdfSmart Architecture ESSENTIAL GUIDE Smart Solutions for Building and Architecture - Multi-lingual
SmartArchitecture-low.pdfSilicone, Vinyl Spacer and Wall Anchor Installation System
SGB-042-Glass-Block-Wall-Anchor-Vinyl-Spacer-Silicone-1.pdfSilicone Installation Instructions Pegasus Line (English and Spanish)
SGB-039-Silicone-Manual-Pegasus-EN_ES.pdfVetroKWiKTM - Vetropieno Installation System
SGB-034-VetroKWiK-Installation-System.pdfProVantage® Silicone Installation System - English and Spanish
SGB-032-ProVantage-Silicone-Installation-System-06_28_21-EN_ES.pdfLightWise® Architectural Precast Concrete Panel Systems & Glass Paver Literature
SGB-029-HorizontalApplications-12_18_20.pdfSeves Photovoltaic Horizontal Pavers
SGB-024-Photovoltaic-Horizontal-Pavers.pdfSEVES Multi-Surface 1Part Silicone Sealant Technical Data Sheet
SGB-021-SEVES-SILICONE-TDS.pdfMULTI-SURFACE 1PART INDUSTRIAL/CONSTRUCTION GRADE SILICONE SEALANT
SGB-020-SEVES-SILICONE-Prod.pdfMortar and Panel Anchor, Wire Reinforcement Construction Assembly
SGB-019-Glass-Block-Panel-Anchor-Wire-Reinforcement.pdfFire-Rated Glass Block Window Assemblies
SGB-018-Fire-Rated-Brochure_low.pdfSolar Wall Tubes Installation Instructions
SGB-017-Solar-Wall-Tubes-Installation-Instructions.pdfResidential Prefabricated Hurricane-Resistant Windows Installation Guide
SGB-013-Residential-Prefabed-Hurricane-Resistant-Windows-Installation-Guide.pdfLightWise® Architectural Security And Detention
SGB-012-LW-Security-And-Detention.pdfLightWise® Architectural Blast Resistant Window Literature
SGB-011-LWA-Blast-Resistant.pdfLightWise® Architectural Hurricane Resistant Window Literature
SGB-010-LWA-Hurricane-Resistant.pdfLightWise® Architectural Tornado Resistant Window Literature
SGB-009-LWA-Tornado.pdfSeves LightWise® Architectural Systems Warranty
SGB-006-SEVES-LWA-WARRANTY-08-2020-1.pdfPrefabricated Glass Block Panels
SGB-004-Prefabricated-Glass-Block-Panels-2.pdfMortar Glass Block Installation System - Assembly Instructions in English and Spanish
SGB-002-Mortar-Install-System-EN-ES.pdfSafety Glazing KWiK'N-EZTM / ProVantage®
41649.02-119-37-r0-Safety-Glazing-Kwikn-EZ-1.pdfSeves Glass Block Safety Glazing Exemption
2024-08-19-SGB-Safety-Glazing-Exemption-copia.pdfSafety Glazing - 2018 International Residential Code
Safety-Glazing-2018-IRC.pdfSafety Glazing - 2018 International Building Codes
Safety-Glazing-2018-IBC.pdfVERTICAL REINFORCEMENT - Pegasus Q19 Glass End Block Linear Free Standing Wall-Detail
Q-454-VERTICAL-REINFORCEMENT-GLASS-END-BLOCKS-LINEAR-FREE-STANDING-WALL-DETAIL-1.pdfVERTICAL STIFFENER - Pegasus Q19 Glass Block with Hidden Intermediate Vertical Support in Multiple Horizontal Panels-Detail
Q-453-VERTICAL-STIFFENER-HIDDEN-INTERMEDIATE-VERTICAL-SUPPORT-IN-MULTIPLE-HORIZONTAL-PANELS-DETAIL-1.pdfVERTICAL STIFFENER - Pegasus Q19 Glass Block I Intermediate Vert Support in Multiple Horizontal Panels-Detail
Q-452-VERTICAL-STIFFENER-I-INTERMEDIATE-VERT-SUPPORT-IN-MULT-HORZ-PANELS-DETAIL-1.pdfVERTICAL STIFFENER - Pegasus Q19 Glass Block T Intermediate Support in Multiple Horizontal Panels-Detail
Q-451-VERTICAL-STIFFENER-T-INTERMEDIATE-SUPPORT-IN-MULTIPLE-HORIZONTAL-PANELS-DETAIL-1.pdfVERTICAL STIFFENER - Pegasus Q19 Ceiling & Floor Intermediate Support Multiple Horizontal Panels-Detail
Q-450-VERTICAL-STIFFENER-CEILINGFLOOR-INTERM-SUPP-MULT-HORZ-PANELS-DETAIL-1.pdfSILL - Pegasus Q19 Glass Block in Partition Wall-Detail
Q-433-SILL-GLASS-BLOCK-IN-PARTITION-WALL-DETAIL-1.pdfSILL - Pegasus Q19 Glass Block at Concrete Slab-Detail
Q-432-SILL-GLASS-BLOCK-AT-CONCRETE-SLAB-DETAIL-1.pdfSILL - Pegasus Q19 Glass Block Window at Interior Concrete Curb-Detail
Q-431-SILL-WINDOW-AT-INTERIOR-CONCRETE-CURB-DETAIL-1.pdfJAMB - Pegasus Q19 Glass Block in Concrete or Masonry Wall-Detail
Q-423-JAMB-GLASS-BLOCK-PERPENDICULAR-TO-METAL-STUD-PARTITION-DETAIL-1.pdfJAMB - Pegasus Q19 Glass Block in Concrete or Masonry Wall-Detail
Q-422-JAMB-GLASS-BLOCK-IN-CONCRETE-OR-MASONRY-WALL-DETAIL-1.pdfJAMB - Pegasus Q19 Glass Block in Metal Stud Wall Partition-Detail
Q-421-JAMB-GLASS-BLOCK-IN-METAL-STUD-WALL-PARTITION-DETAIL-1.pdfJAMB - Pegasus Q19 Glass Block in Isolated Wall Partition-Detail
Q-420-JAMB-GLASS-BLOCK-IN-ISOLATED-WALL-PARTITION-DETAIL-1.pdfHEAD - Pegasus Q19 Glass Block at Partition - Suspended Ceiling-Detail
Q-414-HEAD-GLASS-BLOCK-AT-PARTITION-SUSPENDED-CEILING-DETAIL-1.pdfHEAD - Pegasus Q19 Glass Block in Metal Stud Partition - Drop Ceiling-Detail
Q-413-HEAD-GLASS-BLOCK-IN-METAL-STUD-PARTITION-DROP-CEILING-DETAIL-1.pdfHEAD - Pegasus Q19 Glass Block in Concrete Slab-Detail
Q-412-HEAD-GLASS-BLOCK-IN-CONCRETE-SLAB-DETAIL-1.pdfHEAD - Pegasus Q19 Glass Block in Insulated Partition Wall-Detail
Q-411-HEAD-GLASS-BLOCK-IN-INSULATED-PARTITION-WALL-DETAIL-1.pdfPhotovoltaic - US Technical parameters table
PV-US-Technical-parameters-table.pdfHORIZONTAL STIFFENERS - Intermediate Horizontal Shelf Angle Support-Detail
PD-161-HORIZONTAL-STIFFENERS-INTERMEDIATE-HORIZONTAL-SHELF-ANGLE-SUPPORT-IN-MULTIPLE-VERTICAL-PANELS-DETAIL-1.pdfHORIZONTAL STIFFENER - Intermediate Support in Multiple Vertical Panels-Detail
PD-160-HORIZONTAL-STIFFENER-INTERMEDIATE-SUPPORT-IN-MULTIPLE-VERTICAL-PANELS-DETAIL-1.pdfVERTICAL STIFFENER - Intermediate Support in Multiple Horizontal Panels-Detail
PD-150-VERTICAL-STIFFENER-INTERMEDIATE-SUPPORT-IN-MULTIPLE-HORIZONTAL-PANELS-DETAIL-1.pdfPD-134-SILL - GLASS BLOCK IN CMU WALL w BRICK VENEER DETAIL
PD-134-SILL-GLASS-BLOCK-IN-CMU-WALL-w-BRICK-VENEER-DETAIL-1.pdfPD-133-SILL - GLASS BLOCK IN CMU WALL w SYNTHETIC PLASTER DETAIL
PD-133-SILL-GLASS-BLOCK-IN-CMU-WALL-w-SYNTHETIC-PLASTER-DETAIL-1.pdfSILL - Glass Block in Concrete Floor Slab-Detail
PD-132-SILL-GLASS-BLOCK-IN-CONCRETE-FLOOR-SLAB-DETAIL-1.pdfSILL - Glass Block in Metal Stud Wall with Brick Veneer-Detail
PD-131-SILL-GLASS-BLOCK-IN-METAL-STUD-WALL-w-BRICK-VENEER-DETAIL-1.pdfSILL - Glass Block in Metal Stud Wall w Synthetic Plaster-Detail
PD-130-SILL-GLASS-BLOCK-IN-METAL-STUD-WALL-w-SYNTHETIC-PLASTER-DETAIL-1.pdfPD-125-JAMB - GLASS BLOCK IN CMU WALL w BRICK VENEER DETAIL
PD-125-JAMB-GLASS-BLOCK-IN-CMU-WALL-w-BRICK-VENEER-DETAIL-1.pdfPD-124-JAMB - GLASS BLOCK IN CMU WALL w SYNTHETIC PLASTER - DETAIL
PD-124-JAMB-GLASS-BLOCK-IN-CMU-WALL-w-SYNTHETIC-PLASTER-DETAIL-1.pdfJAMB - Glass Block Perpendicular to Partition-Detail
PD-123-JAMB-GLASS-BLOCK-PERPENDICULAR-TO-PARTITION-DETAIL-1.pdfJAMB - Hollow Metal Door Frame at Glass Block-Detail
PD-122-JAMB-HOLLOW-METAL-DOOR-FRAME-AT-GLASS-BLOCK-DETAIL-1.pdfJAMB - Glass Block in Metal Stud Wall w Brick Veneer-Detail
PD-121-JAMB-GLASS-BLOCK-IN-METAL-STUD-WALL-w-BRICK-VENEER-DETAIL-1.pdfJAMB - Glass Block in Metal Stud Wall w Synthetic Plaster-Detail
PD-120-JAMB-GLASS-BLOCK-IN-METAL-STUD-WALL-w-SYNTHETIC-PLASTER-DETAIL-1.pdfPD-116-HEAD - BLOCK IN CMU WALL w BRICK VENEER DETAIL
PD-116-HEAD-BLOCK-IN-CMU-WALL-w-BRICK-VENEER-DETAIL-1.pdfPD-115-HEAD - BLOCK IN CMU WALL w SYNTHETIC PLASTER DETAIL
PD-115-HEAD-BLOCK-IN-CMU-WALL-w-SYNTHETIC-PLASTER-DETAIL-1.pdfHEAD - Glass Block in Suspended Ceiling-Detail
PD-114-HEAD-GLASS-BLOCK-IN-SUSPENDED-CEILING-DETAIL-1.pdfHEAD - Glass Block in Metal Stud Partition Wall-Detail
PD-113-HEAD-GLASS-BLOCK-IN-METAL-STUD-PARTITION-WALL-DETAIL-1.pdfPD-112-HEAD - Hollow Metal Door Frame at Glass Block Construction Detail
PD-112-HEAD-HOLLOW-METAL-DOOR-FRAME-AT-GLASS-BLOCK-DETAIL-1.pdfHEAD - Glass Block in Metal Stud Wall w Brick Veneer-Detail
PD-111-HEAD-BLOCK-IN-METAL-STUD-WALL-w-BRICK-VENEER-DETAIL-1.pdfHEAD - Block in Metal Stud Wall w Synthetic Plaster-Detail
PD-110-HEAD-BLOCK-IN-METAL-STUD-WALL-w-SYNTHETIC-PLASTER-DETAIL-1.pdfVistabrik® - Fire Rated N.A.M.I. Certification NI013767 (90min)
Vistabrik.pdf884 Spray Thickset 60 - Fire Rated N.A.M.I. Certification NI013738-R2 (60min)
Vetropieno.pdf884 Spray Thickset 60 - Fire Rated N.A.M.I. Certification NI013738-R2 (60min)
Spray-60.pdf884 Nubio Thickset 90 - Fire Rated N.A.M.I. Certification NI013745 (90min)
Nubio-90.pdf884 Nubio Thickset 60 - Fire Rated N.A.M.I. Certification NI013737-R1 (60min)
Nubio-60.pdf884 Endura Thickset 90 - Fire Rated N.A.M.I. Certification NI013736 (90min)
Endura-90.pdf884 Clarity Thickset 90 - Fire Rated N.A.M.I. Certification NI013735.01 (90min)
Clarity-90.pdf884 Clarity Thickset 60 - Fire Rated N.A.M.I. Certification NI013734-R1 (60min)
Clarity-60.pdfMiami/Dade NOA Residential Hurricane Resistant Windows w THICKSET® 90 and ProVantage® System.pdf - Small & Large Missile Impact (Lightwise® / Residential)
Miami-Dade-NOA-20111008-Residential-Hurricane-Resistant-Windows-w-THICKSET®-90-and-ProVantage®-System.pdfMiami/Dade NOA - 4” Thick Hollow and 3” Thick Solid Glass Block Systems with Mortar - Small Missile Impact Resistant, (Thickset® 90 and Vistabrik® Only)
Miami-Dade-NOA-20111007-4-Hollow-and-3-Solid-Glass-Block-Systems-with-Mortar.pdfMiami/Dade NOA High Performance Hurricane Resistant Glass Block Panels - Small & Large Missile Impact (LightWise® / Commercial)
Miami-Dade-NOA-20111006-High-Performance-Hurricane-Resistant-Window.pdfSpecification for Installation of Lightwise®/ Architectural Systems using a 2-piece Aluminum Frame
LW-AS-01-00-Specification-for-LWA-Installation_Nov-2017_low.pdfLightWise® Architectural Tornado Window Installation Instructions
Tornado-Window-Instructions-2020.pdfIBC Section 2406 & IRC Section 308.4 Safety Glazing Hazardous Location
IBC-Safety-Glazing-Hazardous-Locations.pdfHurricane-Resistant Glass Block Windows with 2-piece Aluminum Channel and 8"x8" Glass Block Rough Opening Chart
SGB-Hurricane-Windows-RO-8in-Block.pdfHurricane-Resistant Glass Block Windows with 2-piece Aluminum Channel and 6"x6" Glass Block Rough Opening Chart
SGB-Hurricane-Windows-RO-6in-Block.pdfPanel Construction using Channel-Type Restraint
CD-003-Channel-Type-Restraint-DETAIL-1.pdfPanel Construction using SEVES Stainless Steel Panel Anchor
CD-002-SEVES-PANEL-ANCHOR-DETAIL-1.pdfPanel Construction using SEVES Mortar Spacers
CD-001-SEVES-MORTAR-SPACERS-DETAIL_1-1.pdfLightWise® Architectural Tornado Resistant Window Specification
08-88-65-LWA-Tornado-Resistant-Window.pdfLightWise® Architectural Ballistic Resistant Window Specification
08-88-56-LWA-Ballistic.pdfLightWise® Architectural Hurricane Resistant Window Specification
08-88-19-LWA-Hurricane-Resistant-Windows.pdfLightWise® Architectural Commercial Glass Block Windows/Panels Specification
08-80-00-LWA-COMMERCIAL-GLASS-BLOCK-WINDOWS-PANELS.pdfLightWise® Architectural Security & Detention Window Specification
08-56-64-LWA-Security-Detention-Glass-Block-Windows.pdfLightWise® Architectural Blast Resistant Window Specification
08-56-23-LWA-Blast-Resistant.pdfLightWise® Architectural Window Specification
08-44-13-LWA-Glass-Block-Windows.pdfGLASS UNIT Masonry Specification - VetropienoTM
04-23-13-Vetropieno-Mortar-Specifications.pdfGLASS UNIT Masonry Specification - Pegasus Line
04-23-13-Pegasus-Mortar-Specifications.pdfSECTION 04 23 10 Glass Block Solar Wall Tube Specification
04-23-10-LWA-Solar-Wall-Tube.pdfHorizontal Precast Concrete Specification
03-48-19-04-23-16-Precast-Conc-Stair-Treads-Prefab-Glass-Block-Panel.pdf
Give us a follow!